A building’s walls, windows and airflow can help maintain indoor temperatures between 22°C and 26°C with little reliance on conventional heating or air conditioning. This is the principle behind the 2226 concept, which uses insulation, thermal mass and automated ventilation to regulate indoor conditions.
Essentiel, the first residential building in France using the approach, has opened in Lyon’s Confluence district. Developed by Baumschlager Eberle, the project aims to reduce dependence on mechanical systems by making the building itself responsible for much of its thermal performance.
Follow THE FUTURE on LinkedIn, Facebook, Instagram, X and Telegram
Designing Around Thermal Mass
“It’s not high-tech, we’re talking about a low-tech building,” said Astrid Lampl, architect and project director at Baumschlager Eberle.
Unlike conventional buildings that rely heavily on mechanical heating, cooling and ventilation, the 2226 concept uses insulation and construction materials to regulate temperatures. Its name refers to the target indoor range of 22°C to 26°C.
Insulation limits heat loss in winter and heat gain in summer, while sunlight, occupants and everyday activities contribute warmth.
“Since 2020, we have learnt that if we want thermal mass, we need to build heavy using materials that store heat,” Lampl said. “Thick walls will provide protection from the heat in summer and retain the heat in winter.”
Essentiel uses double-brick walls, partly because brick manufacturing facilities are located nearby. The apartments also feature high ceilings and large windows designed to maximise natural light.
Automated Airflow Without Conventional Ventilation
The building uses a home automation system to monitor indoor and outdoor temperature, humidity, air quality and weather conditions. Automated wooden vents at the windows regulate airflow based on the data collected by sensors.
A rooftop weather station can detect cooler nighttime air and trigger the vents to open automatically. The system also helps manage carbon dioxide levels and maintain comfort during heatwaves.
Lampl said she prefers fresh air that does not pass through mechanical filtration systems, adding that residents had responded positively to the indoor environment.
The ventilation system works alongside the building’s insulation. Thick walls help retain cooler air in summer, while vents can remain closed during extreme outdoor temperatures. Ceiling fans provide additional comfort by making occupants feel cooler.
Regulations Affect The Cost
Essentiel cost 15% more than conventional housing, according to Lampl and project realtor Nexity. The additional expense partly reflects local requirements, including connection to Lyon’s heating network and the installation of reversible, dual-flow mechanical ventilation.
A planned project in La Garenne-Colombes, west of Paris, could offer a different cost comparison. Without a requirement for central heating, it could use lower-cost electric radiators expected to be rarely needed. The development is planned to include 80 homes, with completion targeted for the end of 2028.
“Today, if we were to build a 2226 as we view it, without the constraints we faced in Lyon, we’re certain it would cost the same as conventional buildings, or even less,” Lampl said.
The project highlights how building design, insulation, thermal mass, orientation and ventilation can reduce reliance on energy-intensive systems. However, the Lyon experience also shows that local regulations and infrastructure requirements can significantly affect construction costs.